Instructions for use
1, the company designed and manufactured muffler used to reduce the fan, the export of aerodynamic noise.
2, muffler installation, from the muffler into the (mouth) 1.5 meters to 2 meters should be no obstruction, and pay attention to avoid other noise sources, so as not to affect the normal use of muffler effect.
3, muffler and fan connection flange diameter is inconsistent, can be coupled with the transition tube, but the equivalent angle should not be greater than 30 °. Connect the flange should avoid rigid connection, and pay attention to seal, to prevent leakage, leakage.
4, muffler can be installed according to actual needs in any position in the space, but should pay attention to the support of the muffler. Muffler can not withstand external weight.
5, muffler should be installed in the air flow channel smooth section, in particular, to avoid installation in the pipe elbow.
6, through the muffler gas dust content should be less than 100 mg / standard cubic meters, or to install the air filter, so as not to affect the use of results.
7, through the silencer media is not allowed to contain water mist, oil mist and corrosive gases. The medium temperature should not be less than 150 ℃.
8, muffler used after a period of time. If the fouling effect is reduced, can only use dry brush to remove dust, and can not rinse with water.
9, muffler in the transport and to be installed before to take moisture, anti-fouling measures, so as not to affect the normal use of the future effect.
10, to meet the above conditions of use, the life of the muffler is usually up to 8-10 years.
F type muffler
Muffler is because the domestic more mature resistance composite muffler, which is mainly used to reduce the various high-pressure centrifugal fan import and export of aerodynamic noise, especially for the fan industry 9-19,9-26 and other models of high-pressure centrifugal fan The
F-type muffler is divided into A, B two forms. A-type ends are flanges, can be used in series in the pipeline, B-type one end of the flange, the other end of the rain suction hood. Can be used for the use of exhaust.
F-type muffler using air flow 2000-66000m3 / h, the use of temperature below 150 ℃, muffler up to 20-25dB (A), the resistance loss is less than 300mmH2O (294pa).
F type muffler specifications selection table
FA, FB muffler dimensions
Z type muffler
I designed and developed by the company's Z-type muffler series a total of nine specifications, of which Z1-Z5 for the resistive muffler. Z5A-Z7 for the impedance composite muffler, Z-type muffler is mainly used to reduce the Roots blower into the exhaust noise.
Z-type muffler for the air volume of 0.25m3 / min-250m3 / min, muffler up to 20-25dB (A), the resistance loss is less than 50mmH2O (490Pa)
Z-type muffler according to the need for the Roots blower into the inlet and outlet flange can also be connected in series, into the pipeline in the use.
Z-type muffler specifications selection table
L - type Roots blower supporting muffler specifications selection table
L-type Roots blower is a joint design of the series Roots blower. I am supporting the design of the L-type muffler, flange can be directly connected. Muffler and resistance loss are similar to Z-type muffler.
L - type Roots blower supporting muffler specifications selection table
PZA disc type muffler
PZA-type muffler is my company introduced the use of imported technology to develop a new round of the intake of the resistance of the muffler. Because of its appearance was discoid. So it has the characteristics of small axial size. It is most suitable for reducing the import noise of small industrial boiler blowers, in the layout of a compact boiler room to use, more both light weight, small footprint, easy installation advantages.
PZA type muffler used in the air flow 3500-15000m3 / h. Muffler 14-18dB (A), resistance less than 10mmH20 (98Pa)
PZA-type disc muffler has won the third prize of scientific and technological progress of machinery industry.
PZA type muffler exterior size diagram
PZB type shielded rectangular muffler
PZB-type muffler is based on the PZA-type muffler, the design developed from its original shape from the original disc into a rectangular, and in the upper and lower with two shielded sound-absorbing panels, After the PZB-type muffler, not only to maintain the PZA-type muffler good performance, and the structure is more compact and reasonable, an increase of rain measures, suitable for outdoor use. PZB-type shielded rectangular muffler in 1989 won the national utility model patents.
PZB type shielded rectangular silencer specifications selection table
PZB type muffler exterior size diagram
DZ type power station blower muffler
DZ-type power station muffler, is the use of the company to introduce the German company Babcock muffler noise reduction technology to create large-scale chip resistive muffler, its birth to effectively solve the 50,000 kw power station - 600,000 kw power station large blower import noise.
DZ muffler for the amount of 30-300m3 / S, the amount of sound is greater than 20dB (A), the resistance is less than 200mmH20 (196Pa).
DZ large-scale power plant muffler has won the Shanghai Municipal Science and Technology Progress Award.
DZ type power station blower muffler specifications selection table
Dimension diagram of DZ type muffler

DZL vertical muffler
DZL vertical silencer appearance dimensions
激情亚洲另类图片区小说区| 蜜桃尤物在线视频免费看| 亚洲唯美清纯卡通动漫视频| 亚洲日韩欧美制丝袜国产| 太粗大进不去倒刺带钩| 日产乱码一二三区别视频| 无码不卡av东京热毛片| 美女人妻少妇一区二区三区| 亚洲中文字幕在线19页| 制服丝袜人妻在线中文字幕| 国产欧美精品区一区二区| 欧洲中字中文字幕第一区| 爆草留学生在线| 亚洲 综合社区| 欧美猛少妇色xxxxx| 两个女人互添下身高潮| 国产极品视频一区二区三区| 天天碰天天爽夜夜爽av| 天天干天天色天天干天天| 国产日韩一区二区三区电影| 亚洲日韩av无码精品放毛片| 加勒比一区二区三区91| 韩国av视频在线看网站| 就要鲁,就要鲁在线观看| 亚洲高清国产拍精品影院| 成人AV片无码免费网站| 无码专区视频精品老司机| 精品国产乱码久久夜夜嗨| 精品人妻av区三上悠亚| 久久久久久一区二区毛片| 精品极品国产呦在线观看| 欧美日韩中文精品一本通| 我和小雪的故事| 国产亚洲午夜久久久久久久| 久久精品国产精品亚洲综合| 成人精品一区二三区熟女| 国产综合精品久久久久成| 亚洲国产欧美不卡在线观看| 精品国产制服丝袜高跟| 岛国片在线免费观看一区| 女生免费露BB在线观看|